Fan Filter Inspection and Cleaning MV-5/MV-10

The air filter located on the front of the chassis should be inspected on a regular basis (at least once a month) and cleaned at the first sign of dust or dirt buildup. Regular cleaning prolongs the life of the filter. If the filter becomes clogged or unusable, you need to order a new air filter. The Adept part number is 40340-00030.

The Inspection/Cleaning procedure is as follows:

  1. Turn off the controller.

  2. Loosen the two screws on the fan filter cover to gain access to the filter; see Figure below.

  3. Pull the air filter out and inspect for dust or dirt. If cleaning is required, use compressed air to clean the filter. (Follow safety procedures regarding the use of compressed air.)

  4. Replace the air filter and secure the filter holder.

 

 

Last modified on: 01/24/2006