Table 4-1. Changed Utility Disk Files
| Utility Disk |
Program Version |
Description of the Changes |
| Version |
P/N Rev Letter |
File Name |
| 12.0 |
A |
CONFIG_C |
12.0D |
Changes for use with V+ 12.2:
· Support software options introduced for V + 12.2
· Support new vision frame-buffer size 992x1014
· Store the local IP address in the controller NVRAM (and eliminate it from the system configuration data)
|
| B |
SAFE_UTL |
11.4A |
Fix bugs in the brake-holding test. |
| C |
ADV_CAL |
11.4A |
Fix minor bug associated with saving/ restoring switches and parameters. |
| CONFIG_C |
12.0D1 |
Fix bug in installing palletizer system. Include the latest edition of DISKCOPY. |
| DISKCOPY |
11.2G |
Change order of copying V+ system files. Empty \CALIB\ when copying V+ system. |
| FORMAT |
11.1D |
Reduce sizes of some system files to reduce the space required on a backup diskette created by copying the V+ system from the hard drive. |
| FTP_CLNT |
11.1D |
Fix bug that could cause the number of available TCP connections to decrease over time. |
| FTP_SRVR |
11.1C |
| SAFE_UTL |
11.4B |
Fix bug in the voltage-restrict test. |
| D |
SAFE_UTL |
11.4C |
Add support of Adept 558/559 robots. |
| 12.1 |
A |
DUTY_CYC |
12.1A1 |
Release new program for use with Adept XL robots. |
| SAFE_UTL |
12.1B |
Add support of AdeptThree-XL robot. |
| SFUTIL |
12.1C |
Add support of Adept XL robots. |
| SPEC |
12.1B3 |
Add support of AdeptModules devices. |
| \SPECDATA\ |
|
Include SPEC data files for AdeptModules devices (see the AdeptModules Instruction Handbook, Volume 1, Adept MV Controller Interface). |
| B |
\SPECDATA\ |
|
Fix bug in SPEC data files for extended H and M AdeptModules units. |
| 12.2
|
A |
ADVSERVO |
12.2C2 |
Now distributed on this disk instead of a separate distribution diskette. Enhanced to support reading external encoders (see the Advanced Servo Library Reference Guide). |
| BELT_CAL |
11.2A |
Add option to "flip" the nominal belt transformation after the calibration procedure. Improve support of the AdeptOne-XL, AdeptThree-XL, and Adept Cobra 600. Add check for no robot and for robot not calibrated, to prevent the program from "hanging" in those situations. |
| CONFIG_C |
12.2C |
Permit elements of the local IP address to be set to zero. |
| EXAMPLES |
12.2A |
Part of the ADVSERVO package-now distributed on this disk instead of a separate distribution diskette (see the Advanced Servo Library Reference Guide). |
| SAFE_UTL |
12.2B |
Add support of AdeptOne-XL and Adept Cobra 600 robots. |
| SPEC |
12.2C |
Add support of the Z/Theta mechanism. Add support of data for detection of collisions with Cartesian obstacles. |
| \SPECDATA\ |
|
Add support of the Z/Theta mechanism. Change SPEC data files to use MODULES.CAL instead of STANDARD.CAL. |
| 12.3 |
A |
ADVSERVO |
12.3A1 |
Added support for:
· New features of SPEC (see below).
· Accessing opcodes 2xxx.
Fixed bug preventing sl.exttrip from triggering data collection. |
| CONFIG_C |
12.3B |
Included the latest edition of DISKCOPY |
| DISKCOPY |
11.3C |
Reduced the amount of diskette space needed when copying a V+ system to diskette from the hard drive. |
| SPEC |
12.3A1 |
Added support for:
· Defining both accel and decel for point-to-point move tests
· NFS reading/writing SPEC data files
· Opcode 1064 "Manual Mode Envelope Error Limit".
· AdeptModules "cal to home" capability.
· User defined point-to-point test routine. Modified sp.tu.move.test( ) to facilitate an understanding of custom point-to-point motion routines. Also, changed calling sequence so that the motion control data array is passed to the point-to-point motion routine.
Other changes:
· Now prevent *Robot Interlocked* error during cal teaching.
|
|
|
|
\SPECDATA\ |
|
Minor change to the file for the Z/Theta mechanism, to correct the maximum acceleration. |
| 12.3 |
B |
ADV_CAL |
11.4B |
Fix bug in loading belt calibration file and graphics. |
| CONFIG_C |
12.3B2 |
Include the latest edition of DISKCOPY. Added support of accessing the NVRAM with V+ version 12.4. |
| DISKCOPY |
11.3D |
Further reduce the amount of diskette space needed when copying a V+ sysetm to diskette from the hard drive. |
| SQUEEZE |
3.6 |
Correct the processing of input files not created by V+. |
| \SPECDATA\ |
|
Minor change to the file for the Z/Theta mechanism, to correct a problem with J3 calibration. |
| 12.4 |
A |
ADVSERVO |
12.4A4 |
Added support for:
· New features of SPEC (see below).
Added new routine sl.rw.ready. Fixed undefined value bug in sl.c.where and sl.where. Fixed "loc" data returned by sl.c.where. Included the latest editions of the routines for accessing SPEC data and files. |
|
|
|
CONFIG_C |
12.4A4 |
Added support for three LOCAL.SERIAL ports. Included the latest editions of the routines for accessing SPEC data and files. |
| SAFE_UTL |
12.4A |
Included the latest editions of the routines for accessing the controller NVRAM. |
| SFUTIL |
12.4A2 |
Included the latest editions of the routines for accessing SPEC data and files |
| SPEC |
12.4B4 |
Added support to frequency response tests for:
· Testing multiple frequency bands
· Specifying start and stop amplitude
· Linear spacing of input amplitudes
· Display of amplitudes used
· ASCII file export of test data (with option for including a document description)
Other changes:
· Added STOP test option to the Robot/Motor Servo Tuning menu
· Added support for Static Friction Feedforward Compensation
· Added prompt for including a document description for all SPEC-generated files
· Miscellaneous bug fixes
|
|
|
|
/SYSTEM/ |
|